Kripal UKB7Z-63 2P 63A 500V DC Miniature Circuit Breaker
₨ 1,500
- Rated current: 63 A
- Rated voltage: 500 V DC (2P)
- Breaking capacity: up to 6 kA
- Trip curve: C (instantaneous 7–15 × In)
- Original Kripal, delivery across Pakistan
Kripal UKB7Z-63 2P DC breaker price in Pakistan
The Kripal UKB7Z-63 2P 63A 500V DC Miniature Circuit Breaker price in Pakistan at HN Electric is shown at the top of this page. KRIPAL is a Yueqing (China) switchgear manufacturer whose UKB7Z series is made specifically for DC circuits such as PV combiner boxes and battery banks. It trips automatically on overload or short circuit on the DC side and can also be used as a switch to isolate the line during service. In 2-pole form it is rated 500 V DC with both poles in series, a good fit for battery lines, small solar strings and DC loads. Breaking capacity is 6 kA.
Specifications
| Model | KRIPAL UKB7Z-63, 2-pole |
|---|---|
| Rated current | 63 A |
| Rated voltage | 500 V DC (2P) |
| Breaking capacity | up to 6 kA |
| Trip curve | C (instantaneous 7–15 × In) |
| Impulse withstand | 6 kV |
| Polarity | Polarised – connect + / − exactly as marked |
| Contact indicator | Yes (ON/OFF window) |
| Standard | IEC/EN 60898 |
| Mounting | 35 mm DIN rail, 2 modules |
Specifications from the KRIPAL official product page (kripal.net). Images: Kripal.
Where to use it
- Battery-to-inverter or battery-to-charge-controller protection on 12, 24 and 48 V systems (within the rated current)
- Small solar strings and DC water-pump circuits within the voltage rating
- DC loads such as DC fans, CCTV, routers and telecom supplies
- Spare protection inside solar DB boxes for future expansion
Pakistan installation example
Many homes in Faisalabad, Multan and Karachi run a 12/24 V lithium battery with a small inverter or a solar fan setup to get through load-shedding. A DC breaker sized just above the normal operating current – for example 32 A for a 24 V line that runs up to about 25 A – protects the cable and the battery terminals if a short happens. For a 48 V inverter battery line that draws more than 63 A, use a DC MCCB instead.
Installation and selection tips
- This is a DC breaker – never substitute an AC MCB on the DC side; DC arcs do not self-extinguish at a zero crossing.
- Follow the + / − and LOAD markings printed on the breaker; on polarised DC breakers a reversed connection may not break the arc properly.
- Keep the breaker voltage above your circuit voltage; for strings above 500 V choose a 4-pole 1000 V breaker.
- Size the current at roughly 1.25 × panel Isc for a PV string, or just above the inverter’s maximum battery current for a battery line.
- Use 4–6 mm² copper solar cable, tighten the terminals firmly and re-check them after the first summer – loose DC terminals are the main cause of melted breakers.
- Fit it inside a ventilated DB box out of direct sun, and add a DC SPD on the same line for lightning protection.
Complete your solar DC protection
Pair it with the Tomzn 2P DC 1000V Solar Mini Circuit Breaker, CNC YCB8-63PV 4P DC 1000V 63A Solar DC MCB Breaker, Mora 2P DC 1000V Solar MCB, TOMZN DC SPD 1000V 2P Solar Surge Protection Device, Mora AESPV32 ELR1 Solar PV DC Isolator Switch 32A and 6mm Flexible DC Heatproof Wire – Solar Cable. Browse all circuit breakers and solar products, or read our guides: DC breaker size for a 10kW solar system, best 1000V DC solar MCBs for PV protection and DC isolator vs DC breaker.
Why buy from HN Electric
Original Kripal stock, delivery across Pakistan and free sizing help from our team on WhatsApp – send your panel and inverter model and we will tell you the right breaker, fuse and connector ratings.
FAQs
What is the Kripal UKB7Z-63 2P DC breaker price in Pakistan?
The Kripal UKB7Z-63 2P DC breaker price in Pakistan at HN Electric is shown at the top of this page. Stock and prices can change, so confirm on WhatsApp before ordering.
Can I use an AC breaker on the solar DC side?
No. A DC fault arc does not go out on its own like an AC arc, so an AC MCB may fail to break it. Always use a DC-rated breaker on the panel and battery side.
What voltage is the Kripal UKB7Z-63 2P DC breaker rated for?
500 V DC with both poles in series (250 V DC per pole).
Which amp rating should I choose?
For a PV string take about 1.25 × the panel short-circuit current (most 580 W panels need 20 A or 32 A). For a battery line use a rating just above the inverter’s maximum battery current. Send us your panel and inverter model on WhatsApp and we will size it free.
Is the Kripal DC breaker original?
Yes. HN Electric supplies original Kripal stock; check the printed model number (KRIPAL UKB7Z-63) and the breaker markings when you receive it.
DC breaker kitne ka hai aur kahan lagta hai?
Yeh Kripal UKB7Z-63 2P DC breaker HN Electric par (live price upar dekhein) ka hai. Yeh solar panels aur inverter ke darmiyan (ya battery aur inverter ke darmiyan) lagta hai taake short circuit ya overload par DC line foran kat jaye.
Only logged in customers who have purchased this product may leave a review.
Shipping & Delivery Across Pakistan
HN Electric carefully packs electrical and solar products for delivery across Pakistan. Delivery time and charges depend on the destination, product size and courier availability, and are confirmed during order processing.
Before You Order
- Confirm the product rating, quantity and delivery address before checkout.
- Contact our team for urgent orders, bulk quantities or installation guidance.
- Inspect the parcel on arrival and report any transit damage promptly.
Need a delivery estimate or technical help? Contact HN Electric on WhatsApp before placing your order.

Reviews