GA&DA GDDC5-63 4P DC 1000V Solar Miniature Circuit Breaker (32A / 63A)
₨ 4,700
- Rated current options: 32 A or 63 A – same price, tell us which one when you order
- Rated voltage: 1000 V DC (4P)
- Insulation voltage: 1000 V
- Breaking capacity: 6 kA
- Original GA&DA, delivery across Pakistan
GA&DA GDDC5-63 4P DC breaker price in Pakistan
The GA&DA GDDC5-63 4P DC 1000V Solar Miniature Circuit Breaker (32A / 63A) price in Pakistan at HN Electric is shown at the top of this page. GA&DA is a switchgear brand already familiar to Pakistani installers for its SPDs, and the GDDC5-63 is its DC MCB for solar and battery systems. It trips automatically on overload or short circuit on the DC side and can also be used as a switch to isolate the line during service. With four poles in series it is rated 1000 V DC, which is what a modern high-voltage PV string on a 6–12 kW hybrid or on-grid inverter needs. Breaking capacity is 6 kA.
Specifications
| Model | GA&DA GDDC5-63, 4-pole |
|---|---|
| Rated current options | 32 A or 63 A – same price, tell us which one when you order |
| Rated voltage | 1000 V DC (4P) |
| Insulation voltage | 1000 V |
| Breaking capacity | 6 kA |
| Impulse withstand | 6 kV |
| Trip curve | C |
| Electrical / mechanical life | 8,000 / 10,000 operations |
| Standard | IEC/EN 60947-2 |
| Mounting | 35 mm DIN rail, 4 modules |
Specifications from the GA&DA official product page (cngandian.com). Images: GA&DA.
Where to use it
- PV string protection between the roof isolator / combiner box and the inverter on 600–1000 V strings
- One breaker per MPPT input on two-MPPT hybrid inverters
- Commercial roof-top combiner boxes for factories, schools and shops
- Isolating the array while the inverter is serviced
Pakistan installation example
A 10 kW house in Lahore or Islamabad usually runs two strings of 10–11 panels of 580–585 W. Each string’s open-circuit voltage is around 500–550 V and climbs on cold winter mornings, so a 4-pole 1000 V breaker per string leaves safe head-room. During load-shedding the inverter pulls everything from the panels and batteries, and this is exactly when a loose DC joint or reverse fault can overheat – a proper DC breaker clears it before it becomes a fire.
Installation and selection tips
- This is a DC breaker – never substitute an AC MCB on the DC side; DC arcs do not self-extinguish at a zero crossing.
- Follow the + / − and LOAD markings printed on the breaker; on polarised DC breakers a reversed connection may not break the arc properly.
- Wire the four poles in series exactly as shown on the breaker diagram to get the full 1000 V rating.
- Size the current at roughly 1.25 × panel Isc for a PV string, or just above the inverter’s maximum battery current for a battery line.
- Use 4–6 mm² copper solar cable, tighten the terminals firmly and re-check them after the first summer – loose DC terminals are the main cause of melted breakers.
- Fit it inside a ventilated DB box out of direct sun, and add a DC SPD on the same line for lightning protection.
Complete your solar DC protection
Pair it with the Tomzn 2P DC 1000V Solar Mini Circuit Breaker, CNC YCB8-63PV 4P DC 1000V 63A Solar DC MCB Breaker, MORA 4P DC 1000V circuit breaker, TOMZN DC SPD 1000V 2P Solar Surge Protection Device, Mora AESPV32 ELR1 Solar PV DC Isolator Switch 32A and 6mm Flexible DC Heatproof Wire – Solar Cable. Browse all circuit breakers and solar products, or read our guides: DC breaker size for a 10kW solar system, best 1000V DC solar MCBs for PV protection and DC isolator vs DC breaker.
Why buy from HN Electric
Original GA&DA stock, delivery across Pakistan and free sizing help from our team on WhatsApp – send your panel and inverter model and we will tell you the right breaker, fuse and connector ratings.
FAQs
What is the GA&DA GDDC5-63 4P DC breaker price in Pakistan?
The GA&DA GDDC5-63 4P DC breaker price in Pakistan at HN Electric is shown at the top of this page. Stock and prices can change, so confirm on WhatsApp before ordering.
Can I use an AC breaker on the solar DC side?
No. A DC fault arc does not go out on its own like an AC arc, so an AC MCB may fail to break it. Always use a DC-rated breaker on the panel and battery side.
What voltage is the GA&DA GDDC5-63 4P DC breaker rated for?
1000 V DC with all four poles connected in series.
Which amp rating should I choose?
For a PV string take about 1.25 × the panel short-circuit current (most 580 W panels need 20 A or 32 A). For a battery line use a rating just above the inverter’s maximum battery current. Send us your panel and inverter model on WhatsApp and we will size it free.
Is the GA&DA DC breaker original?
Yes. HN Electric supplies original GA&DA stock; check the printed model number (GA&DA GDDC5-63) and the breaker markings when you receive it.
DC breaker kitne ka hai aur kahan lagta hai?
Yeh GA&DA GDDC5-63 4P DC breaker HN Electric par (live price upar dekhein) ka hai. Yeh solar panels aur inverter ke darmiyan (ya battery aur inverter ke darmiyan) lagta hai taake short circuit ya overload par DC line foran kat jaye.
Only logged in customers who have purchased this product may leave a review.
Shipping & Delivery Across Pakistan
HN Electric carefully packs electrical and solar products for delivery across Pakistan. Delivery time and charges depend on the destination, product size and courier availability, and are confirmed during order processing.
Before You Order
- Confirm the product rating, quantity and delivery address before checkout.
- Contact our team for urgent orders, bulk quantities or installation guidance.
- Inspect the parcel on arrival and report any transit damage promptly.
Need a delivery estimate or technical help? Contact HN Electric on WhatsApp before placing your order.

Reviews
There are no reviews yet.