







Sogo 615W N-Type Bifacial Solar Panel
Price on WhatsApp
Mora 2P 1000V DC Surge Protection Device – 40kA
₨ 2,999 Original price was: ₨ 2,999.₨ 2,500Current price is: ₨ 2,500.
Mora AES-2040 4Pole 40kA AC SPD
₨ 4,399 Original price was: ₨ 4,399.₨ 3,600Current price is: ₨ 3,600.
- Brand: MORA
- Model: AES-2040
- Configuration: 4-Pole
- Voltage: 385V AC (verify against product label/datasheet)
- Surge Current Capacity: 40kA
- Product Type: AC Surge Protection Device (SPD)
- Mounting: DIN Rail
- Application: Suitable for compatible electrical distribution and protection panels
Brand new, factory seal-packed stock
Open the box and check it on delivery (Cash on Delivery)
Nationwide Cash on Delivery
Tested before dispatch
Estimated shipping time: 48 to 72 hours
Visit our Lahore shop: 1st Floor, A-8/16, H-Block Commercial Zone, Valencia, Lahore. WhatsApp 0329 1654950
Installation and technical support available
SKU:
HN-27854
Category: Surge Protection Devices (SPDs)
Description
Mora AES-2040 4Pole 40kA AC SPD is a DIN-rail surge protection device for compatible three-phase AC distribution systems. When installed in a properly designed panel, it helps divert short-duration transient overvoltages away from sensitive electrical equipment and the AC side of suitable solar inverters.
Mora AES-2040 4Pole 40kA AC SPD Features
- Four-pole arrangement: intended for coordinated protection of three phase conductors and neutral in a compatible system.
- DIN-rail mounting: compact installation inside an appropriate distribution enclosure.
- Visual status indication: supports routine inspection of protection-module condition.
- 40kA stated maximum discharge rating: verify the exact Imax marking on the received unit.
- Replaceable modules: supports practical maintenance where the supplied version uses plug-in cartridges.
Understanding the Electrical Ratings
The “40kA” marking commonly refers to maximum surge discharge current (Imax), not continuous load current. Check the supplied SPD label for maximum continuous operating voltage (Uc), nominal discharge current (In), Imax, voltage protection level (Up), frequency and SPD type or test class. These values must match the real panel design.
The protection level should coordinate with the impulse withstand rating of the protected equipment. The designer should also consider nominal system voltage, prospective fault current, installation category, supply configuration and earthing arrangement. Do not select a three-phase SPD using pole count or the 40kA headline alone.
Typical Applications
- Three-phase commercial and industrial distribution boards
- Workshops, offices and multi-load electrical panels
- Compatible three-phase solar-inverter AC distribution
- Generator and utility-connected three-phase systems
Installation and Earthing Requirements
Installation must be completed by a qualified electrician. Follow the wiring diagram and L1, L2, L3 and neutral markings on the actual device. Use the specified conductor size and terminal torque, and keep connections as short and direct as practical. Long or looped leads raise the effective protection voltage during a surge.
A low-impedance earthing and bonding path is essential. The SPD cannot compensate for missing earthing, poor bonding or unsuitable cable routing. The installer should provide correctly coordinated upstream backup protection where required and confirm that the neutral arrangement matches the supply system.
An SPD does not replace a circuit breaker, RCCB, voltage protector, earthing system or external lightning-protection design. Browse suitable distribution boxes and more surge protection devices for a coordinated installation.
Inspection and Replacement
Inspect every module’s status window during scheduled panel maintenance and after a known surge or lightning event. If an indicator shows failure, isolate the panel safely and replace the affected module or complete device according to the manufacturer’s instructions. SPDs can degrade after repeated transient events even while the electrical system continues operating.
Selection Checklist
Before ordering, record the line-to-line and line-to-neutral voltages, earthing arrangement, required SPD type, equipment impulse rating, enclosure space and backup-protection requirements. Confirm Uc, Up, In, Imax and the four-pole wiring configuration printed on the supplied unit. Buildings with external lightning protection or exposed incoming services may need additional coordinated SPD stages.
Why Buy from HN Electric?
HN Electric supplies electrical protection products across Pakistan with convenient online ordering. Explore additional Mora electrical products, or share your panel and supply details with our team before ordering if you need help checking compatibility.
Important: Product appearance and label details may vary by batch. Verify the received device and arrange professional installation before energizing the three-phase circuit.
Compatibility note: Confirm whether the installation requires Type 1, Type 2 or coordinated multi-stage surge protection. The correct choice depends on lightning exposure, building wiring and upstream protection. A qualified designer should review high-risk sites, industrial panels and buildings fitted with an external lightning protection system.
Mora AES-2040 4Pole 40kA AC SPD FAQs
What does the 40kA marking mean?
On the Mora AES-2040 4Pole 40kA AC SPD, 40kA normally refers to the stated maximum surge-discharge current, not the continuous load current. Confirm Imax, In, Uc and Up on the supplied unit.
Does this SPD protect against sustained over-voltage?
An SPD is designed for short transient events. Sustained high or low voltage requires suitable voltage-protection equipment, while overload and short-circuit faults require correctly rated breakers or fuses.
Why are short connections and good earthing important?
Long, looped or high-impedance conductors increase the effective voltage reaching protected equipment during a surge. Correct bonding, earthing and conductor routing are essential to SPD performance.
Can this SPD be installed without backup protection?
Backup protection requirements depend on the SPD markings, prospective fault current and manufacturer instructions. A qualified electrician should design and install the coordinated system; general standards information is available from the International Electrotechnical Commission.
Reviews (0)
Only logged in customers who have purchased this product may leave a review.
Shipping & Delivery
Shipping & Delivery Across Pakistan
HN Electric carefully packs electrical and solar products for delivery across Pakistan. Delivery time and charges depend on the destination, product size and courier availability, and are confirmed during order processing.
Before You Order
- Confirm the product rating, quantity and delivery address before checkout.
- Contact our team for urgent orders, bulk quantities or installation guidance.
- Inspect the parcel on arrival and report any transit damage promptly.
Need a delivery estimate or technical help? Contact HN Electric on WhatsApp before placing your order.
Related products
CHINT 4P 440V AC Surge Protection Device
Rated 0 out of 5
- Brand: Chint
- Type: AC Surge Protection Device (SPD)
- Configuration: 4 Pole / 4P
- Rated system voltage: 440V AC — verify exact device specification before installation
- Mounting: DIN rail
- Protection: Transient surge and overvoltage protection
- Application: Compatible three-phase AC electrical and solar installations
Chint NU6-IIG 2P 40kA 440V AC Surge Protector
Rated 0 out of 5
- 2-Pole (2P) design protects phase & neutral in 230/400V systems
- 40kA surge current rating, 440V max continuous operating voltage
- IEC/EN 61643-11 certified
- Modular replace only the protection module, not the whole unit
- Visual fault/status indicator for quick health checks
- DIN rail mounting, compact footprint
- Ideal for residential, commercial & solar installations
GA&DA G2040PV 2P DC 1000V Surge Protection Device (SPD)
Rated 0 out of 5
Mora AES-2040 AC 2-Pole SPD 40kA 385V
Rated 0 out of 5
MORA SPD 100kA Pakistan Surge Protection
Rated 0 out of 5
- Brand: MORA
- Product Type: Surge Protection Device (SPD)
- Surge Capacity: 100kA
- Designed to help protect compatible electrical systems from transient voltage surges
- Suitable for electrical protection applications where a higher surge-current rating is required
- Verify voltage, pole configuration and technical ratings before installation
- Available from HN Electric with delivery across Pakistan
Noark SPD-2PAC 2P 300V AC Surge Protection Device
Rated 0 out of 5
Schneider SPD DC 1000V Surge Protection Device for Solar Systems
Rated 0 out of 5
- 1000V DC surge protection for compatible solar PV applications
- Designed for protection against transient overvoltage and surge events
- Suitable for compatible solar DBs, PV protection panels and DC systems
- Ideal for solar installers, electricians and residential/commercial PV projects
- Verify PV string voltage and SPD specifications before installation
- Should be coordinated with DC breakers/isolators and proper earthing
- Available from HN Electric with delivery across Pakistan
TOMZN DC SPD 1000V 2P Solar Surge Protection Device
Rated 0 out of 5
- Brand: TOMZN
- Type: DC Surge Protection Device (SPD)
- Maximum PV voltage: Up to 1000V DC, model dependent
- Application: Solar PV, DC distribution and inverter protection
- Installation: DIN-rail mounting
- Protection: Helps protect DC equipment from transient overvoltage
- Design: Fast response and replaceable plug-in protection module

Reviews
There are no reviews yet.