CASMO AES-63 2P 63A 30mA Earth Leakage Circuit Breaker
₨ 1,449
- Brand / model: CASMO AES-63 two-pole earth leakage / RCCB
- Marking on the face: AES-63, 63/0.03, Un 230 V, 50 Hz, IEC/EN 61008
- Rating: 2 pole, 63 A, 30 mA (0.03 A)
- Also marked: Im = IΔm = 630 A, Inc = IΔc = 6000 A
- This is the 2-pole unit — not the 4-pole CASMO ELCB already on our site
- Cash on Delivery across Pakistan, with open-box check
CASMO AES-63 2P 63A 30mA Earth Leakage Circuit Breaker price in Pakistan
The CASMO AES-63 2P 63A 30mA Earth Leakage Circuit Breaker is a two-pole residual-current (earth-leakage) breaker for a single-phase line and neutral. The face is marked CASMO, AES-63, 63/0.03, Un 230 V, 50 Hz, IEC/EN 61008, with a test button. The price in Pakistan at HN Electric is shown at the top of this page.
This is not a second copy of our existing CASMO 4-pole 63 A 30 mA earth-leakage breaker. That 4-pole unit is for three-phase boards. This AES-63 is two modules wide, with two incoming and two outgoing terminals, as shown in the photos.
What the markings mean
- 63/0.03: 63 A rated current and 30 mA (0.03 A) residual-current sensitivity.
- Im = IΔm = 630 A and Inc = IΔc = 6000 A are printed on the face of the unit we photographed. Confirm the same figures on the breaker you receive.
- IEC/EN 61008 is the residual-current breaker standard marked on the body — this is an ELCB / RCCB, not a miniature circuit breaker.
A 30 mA two-pole RCCB is commonly used as additional protection on a single-phase incomer, a water-heater or AC circuit, or a workshop socket line, together with a correctly rated MCB. A qualified electrician should select the rating and the installation method.
CASMO AES-63 2P specifications
| Brand / model | CASMO AES-63 |
|---|---|
| Product type | 2-pole earth-leakage circuit breaker / RCCB |
| Poles | 2P (line and neutral) |
| Rated current | 63 A, as marked 63/0.03 |
| Residual operating current | 30 mA (0.03 A) |
| Rated voltage | Un 230 V, 50 Hz, as marked |
| Standard marked | IEC/EN 61008 |
| Making / breaking markings on the face | Im = IΔm = 630 A; Inc = IΔc = 6000 A |
| Test facility | Push-to-test button on the face |
| Mounting | DIN rail, in a suitable enclosure |
All ratings above are taken from the face and terminals of the unit in the photos. Check the same markings on the breaker you receive before you install it.
FAQ
1. Is this the same as the CASMO 4-pole ELCB already on the site?
No. That listing is the 4-pole 63 A 30 mA CASMO earth-leakage breaker for three-phase boards. This AES-63 unit is two-pole, for a single-phase line and neutral.
2. What does 63/0.03 mean?
On the face it means 63 A rated current and 0.03 A (30 mA) residual-current sensitivity. A 30 mA device is the usual sensitivity for personal protection on a final circuit, subject to the electrician’s design.
3. Does it also provide overcurrent protection like an MCB?
An RCCB / ELCB of this type trips on earth leakage. It does not replace a correctly rated MCB or MCCB for overload and short-circuit protection. Use both where the design requires them.
4. Do you deliver across Pakistan?
Yes, with Cash on Delivery and an open-box check, or collection from the shop in Valencia, Lahore.
You can buy the CASMO AES-63 2P 63A 30mA Earth Leakage Circuit Breaker from HN Electric with Cash on Delivery across Pakistan. On delivery you can open the box and check the markings before you pay. You can also collect it from our shop in Valencia, Lahore. Before you order, message us on WhatsApp at 0329 1654950 to confirm the exact rating, stock, the warranty terms that come with this stock (if any), and delivery time. You can also browse more earth-leakage breakers or other CASMO products or the CASMO 4-pole 63 A 30 mA ELCB.
Only logged in customers who have purchased this product may leave a review.
Shipping & Delivery Across Pakistan
HN Electric carefully packs electrical and solar products for delivery across Pakistan. Delivery time and charges depend on the destination, product size and courier availability, and are confirmed during order processing.
Before You Order
- Confirm the product rating, quantity and delivery address before checkout.
- Contact our team for urgent orders, bulk quantities or installation guidance.
- Inspect the parcel on arrival and report any transit damage promptly.
Need a delivery estimate or technical help? Contact HN Electric on WhatsApp before placing your order.
Related products
ABB RCCB 4 poll Earth Leakage Circuit Breakers
- Genuine ABB RCCB / Earth Leakage Circuit Breaker
- ABB F200 range includes multiple 2P and 4P configurations
- Available ratings vary by exact ABB reference
- Residual-current sensitivity can include 30mA, 100mA and 300mA
- AC, A and specialized B-type options are available within ABB's range
- Designed for residual/earth-leakage protection in compatible electrical installations
- Verify exact poles, ampere, mA sensitivity and RCCB type before ordering
CASMO Earth Leakage Circuit Breaker
- Brand: CASMO
- Earth leakage / residual-current protection
- Available in different pole and current configurations depending on model
- Suitable for residential, commercial and electrical distribution applications
- Check exact ampere, pole and leakage-current rating before purchase
- Designed for installation in compatible electrical distribution systems
- Professional installation is recommended
Green Power 4P 63A Earth Leakage Circuit Breaker
- Brand: Green Power
- Earth leakage / residual-current protection
- Available in different pole and current configurations depending on model
- Suitable for compatible residential, commercial and electrical distribution applications
- Check exact pole, ampere and leakage-current rating before purchase
- Available configurations may include 2P and 4P models
- Professional electrical installation is recommended
Legrand 4P RCCB Earth Leakage Circuit Breakers
- Genuine Legrand RCCB / Earth Leakage Circuit Breaker options
- Available configurations include 2P and 4P, depending on model
- Options can include 30mA, 100mA and 300mA residual-current sensitivity
- Legrand DX³ and TX³ ranges include different current and leakage-protection specifications
- Suitable for appropriate residential, commercial and distribution-board applications
- DIN-rail installation on compatible models
- Select the exact ampere, pole and mA specification before ordering
Mora 2P RCCB 63A
- Brand: MORA
- Rated current: 63A
- Configuration: 2 Pole / 2P
- Type: RCCB (Residual Current Circuit Breaker) — Type AC
- Rated voltage: 230V AC
- Residual sensitivity: 30mA
- Neutral arrangement: Switched neutral (2-pole switching N and L), neutral on left terminal
- System: Single-phase AC distribution
- Suitable for: Residential and light commercial applications
- Use: Earth leakage detection and personnel/equipment safety protection
MORA Bulgaria RCBO 2P 63A
Schneider Vigi Earth Leakage Circuit Breaker
- Genuine Schneider Electric Vigi earth-leakage protection
- Designed to detect residual/earth-leakage current
- Available configurations vary by Schneider reference
- Check exact ampere, poles, mA sensitivity and voltage before ordering
- Vigi products may be integrated breakers or compatible add-on protection modules
- Suitable for appropriate residential, commercial or industrial electrical installations
- Verify breaker/Vigi compatibility before installation