CNC YCB8-63PV 4P 1000V 63A DC Solar Miniature Circuit Breaker

₨ 3,300

  • Poles: 4P (18 mm per pole, 72 mm total)
  • Rated working voltage: 1000 V DC (4 poles in series)
  • Rated current: 63 A (series also made in 1–63 A)
  • Breaking capacity: Icu 6 kA, Ics = 100% Icu
  • Original CNC Electric, delivery across Pakistan
Brand new, factory seal-packed stock
Open the box and check it on delivery (Cash on Delivery)
Nationwide Cash on Delivery
Tested before dispatch
Estimated shipping time: 48 to 72 hours
Visit our Lahore shop: 1st Floor, A-8/16, H-Block Commercial Zone, Valencia, Lahore. WhatsApp 0329 1654950
Installation and technical support available
SKU: CNC-YCB8-63PV-4P-63A Categories: , Tags: ,
Description

CNC YCB8-63PV 4P DC breaker price in Pakistan

The CNC YCB8-63PV 4P DC 1000V 63A Solar DC MCB Breaker price in Pakistan at HN Electric is shown at the top of this page. The YCB8-63PV is CNC Electric’s photovoltaic DC miniature circuit breaker: it trips automatically on overload or short circuit on the DC side, and doubles as a switch to disconnect the line. In 4-pole form the poles are wired in series to reach 1000 V DC, which makes it the right breaker for a high-voltage PV string going into a modern 6–12 kW hybrid inverter. Breaking capacity is 6 kA with Ics = 100% Icu, so it keeps its full rating even after clearing a fault.

Specifications

ModelYCB8-63PV 4P, 63 A
Poles4P (18 mm per pole, 72 mm total)
Rated working voltage1000 V DC (4 poles in series)
Rated current63 A (series also made in 1–63 A)
Breaking capacityIcu 6 kA, Ics = 100% Icu
PolarityPV type – polarised, follow the + / − marking
Trip curveC (8 In ± 20%)
Rated insulation voltage1200 V DC
Rated impulse voltage4 kV
Mechanical / electrical life20,000 / 10,000 operations
Operating temperature−35 °C to +70 °C
Mounting35 mm DIN rail, terminal torque 3.5 N·m
StandardIEC/EN 60947-2, RoHS

Specifications from CNC Electric’s official catalogue. Images: CNC Electric.

Where to use it

  • PV string protection between the isolator / combiner box and the inverter on 600–1000 V strings
  • Two-MPPT systems – one 4P breaker per string
  • Combiner boxes for commercial roof-tops
  • Disconnecting the array while servicing the inverter

Pakistan installation example

A 10 kW house in Islamabad with two strings of 11 × 585 W panels (Voc around 550 V each, cold-morning closer to 600 V) needs a breaker above 600 V – a 4P 1000 V unit per string gives safe head-room. Choose the current a little above the panels’ short-circuit current (Isc × 1.25): for most 580 W panels with Isc around 14 A, a 20 A breaker per string is common; for a battery line, size it to the inverter’s maximum battery current.

Installation tips

  • This is a polarised PV breaker – connect + and − exactly as marked or it may not interrupt the arc properly.
  • Wire the poles in series as shown in CNC’s diagram to get the full voltage rating.
  • Use 4–6 mm² copper solar cable and tighten terminals to 3.5 N·m; loose DC terminals are the main cause of melted breakers.
  • Mount it inside a DB or combiner box away from direct sun – ratings derate at high temperature.
  • Add a DC SPD on the same line for lightning and surge protection.

Complete your solar DC protection

Pair it with the Mora 125A 2P DC MCCB for the battery line, Mora AESPV32 32A PV DC isolator, CNC YCS6-C 2P DC surge protector, 6 mm flexible DC solar cable. Browse all solar products and solar inverters, or read our guide: DC breaker size for a 10kW solar system, plus earthing for a solar system in Pakistan.

Why buy from HN Electric

Original CNC Electric stock, delivery across Pakistan and free sizing help from our team on WhatsApp – send your panel model and inverter, and we will tell you the right breaker, isolator and fuse ratings.

FAQs

What is the CNC YCB8-63PV 4P DC breaker price in Pakistan?

The CNC YCB8-63PV 4P DC breaker price in Pakistan at HN Electric is shown at the top of this page. Confirm current stock on WhatsApp before ordering.

Can I use an AC MCB on the DC solar side?

No. DC arcs do not self-extinguish at a zero-crossing like AC, so an AC MCB can fail to break a DC fault. Always use a DC-rated breaker such as the YCB8-63PV.

What voltage is the CNC YCB8-63PV 4P DC breaker rated for?

1000 V DC with all four poles in series.

Which amp rating do I need?

For a PV string use roughly 1.25 × the panel Isc (often 20 A or 32 A). For a battery line follow the inverter’s maximum battery current. Our team can size it free on WhatsApp.

Kya yeh DC breaker battery ke liye use ho sakta hai?

Ji haan, 63A tak ki battery line par use ho sakta hai. Is se zyada current ke liye DC MCCB lagayein.

Reviews (0)

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Shipping & Delivery

Shipping & Delivery Across Pakistan

HN Electric carefully packs electrical and solar products for delivery across Pakistan. Delivery time and charges depend on the destination, product size and courier availability, and are confirmed during order processing.

Before You Order

  • Confirm the product rating, quantity and delivery address before checkout.
  • Contact our team for urgent orders, bulk quantities or installation guidance.
  • Inspect the parcel on arrival and report any transit damage promptly.

Need a delivery estimate or technical help? Contact HN Electric on WhatsApp before placing your order.